Surtron 400HP

TWIN OPERATIVE ACTIVITY

  • Two output channels for monopolar cutting
  • Two independent setting and output channels for the most frequent monopolar coagulation

CONTROLLED CUTTING PROCEDURES

  • Enhanced cutting current for scar free incision
  • Cutting current with selectable coagulating property for bleeding controlled dissection
  • Low capacitive coupling by Slow Blend current for endoscopic procedures

TWIN CONTROLLED COAGULATIVE PROCEDURES

  • Speedy* coagulation and Deep** coagulation available to two operators
  • Spray coagulation available by hand switch or foot switch

WIDE BIPOLAR FEATURES

  • Bipolar cutting current with selectable bleeding control
  • Slow Blend cutting current
  • Separately activable Automatic Start and Automatic Stop coagulation

SURGEON AND PATIENT TOTAL SAFETY

  • Acceptability of contact impedance between patient body and return electrode continuously watched by Skin Plate Electronic Control (SPEC)
  • Excessive power delivery time warned
  • H.F. Leakage currents continuously monitored
  • Mains voltage variations automatically compensated before to start the delivery of HF power

PERSONALIZED PROCEDURES

  • Independent choice of coagulative currents and power levels by each of two operators
  • Ten personal configurable and immediately recallable procedures

EXTENSION DRIVER AND INTERLOCK SIGNALS

  • Drive output connection to external Argon-Plasma unit and Smoke Evacuator unit

AUTOMATIC SELF DIAGNOSIS

  • Automatic diagnostic control of the actual complete functionality of the electronic unit and the connected accessories coded report of found failures
  • * Speedy coagulation also said Fulgurate or Forced coagulation
  • ** Deep Coagulation also said Pin Point, Desiccate or Soft coagulation

Main Features:

  • Maximum output power monopolar pure CUT (W) 400 → 300Ω
  • Maximum output power monopolar cut-coag CUT80% (W) 300→ 300Ω
  • Maximum output power monopolar cut-coag CUT60% (W) 250 → 300Ω
  • Maximum output power monopolar cut-coag CUT40% (W) 200 → 300Ω
  • Maximum output power monopolar cut ENHANCED (W) 250 → 300Ω
  • Maximum output power monopolar cut-coag BLEND (W) 250 → 500Ω
  • Maximum output power monopolar coagulation SPEEDY (W) 120 → 500Ω
  • Maximum output power monopolar coagulation DEEP (W) 120 → 200Ω
  • Maximum output power monopolar spray-coagulation SPRAY (W) 100 → 2000Ω
  • Maximum output power monopolar spray-coagulation SPRAY ARGON (W) 100 → 2000Ω
  • Maximum output power bipolar CUT (W) 120 → 150Ω
  • Maximum output power bipolar cut-coag CUT 80% (W) 100 → 150Ω
  • Maximum output power bipolar cut-coag CUT 60% (W) 100 → 150Ω
  • Maximum output power bipolar cut-coag CUT 40% (W) 60 → 150Ω
  • Maximum output power bipolar cut-coag BLEND (W) 100 → 300Ω
  • Maximum output power bipolar coagulation COAG (W) 70 → 100Ω
  • Monopolar Working Frequency 425kHz
  • Bipolar Working Frequency 525kHz
  • Selectable power (Vac) 115 – 230
  • Mains frequency (Hz) 50- 60
  • Electrical class (EN60601 – 1) I CF
  • Neutral electrode -F-
  • Weight 8Kg
  • Size 470x150x380mm

Standard Accessories:

  • Unit electrosurgical unit code 10400.90A
  • Power supply cable 5MT 3 x 1.5mm SIEMENS-IEC x1
  • Cable for connection neutral plate x1
  • Blade electrode 7 cm x3
  • Blade electrode 15 cm x3
  • Ball electrode 7cm x3
  • Needle electrode 7cm x3
  • Disposable split neutral electrode x5
  • Disposable handpiece with finger switches x5
  • Reusable handpiece with finger switches x1
  • Instruction’s Manual x1
  • HP250-400 Double water-proof foot-switch x2
  • Electrode cleaning sponge x1
Category: